Â
The products are suitable for the wiring of electric controlling equipments and instrument, monitoring and controlling return circuit ,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750 AC.
Â
Construction
 1. Conductor
   Bare soft copper Class B or Class C concentrically strandedÂ
2. Insulation
   XLPE or PVC, colored for identification
3. Assembly
  Individual conductors are cabled, with non-hygroscopic fillers where necessary, to form a
  round compact core and wrapped with a binder. Two conductor versions are assembled flat
  parallel.
4. Shield
  Aluminum or copper wire, tape or braid
5. Sheath
  Black PVC
Advantages
  Low-capacitance
 Single, pair and multiple conductor available
 Color-coded conductors for easy identification
 Durable, flexible, all-weather jacket
 Available at 600V for general purpose and 1000V for heavy duty
Â
Specification
Â
Type | Name | Section Area(mm2) | No. of Core |
KVV | Copper Conductor, PVC Insulated and Sheathed control cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16Â 19 24 27 30 37 |
4.0Â 6.0 | 2-8 10 12 14 | ||
KVVP | Copper Conductor, PVC Insulated and Sheathed, Copper-braid Screened Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16Â 19 24 27 30 37 |
4.0Â 6.0 | 2-8 10 12 14 | ||
KVVP2 | Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16Â 19 24 27 30 37 |
4.0Â 6.0 | 2-8 10 12 14 | ||
KVVP2-22 | Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Steel-tape armored Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16Â 19 24 27 30 37 |
4.0Â 6.0 | 2-8 10 12 14 | ||
KVV22 | Copper Conductor, PVC Insulated and Sheathed, Steel-tape armored Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16Â 19 24 27 30 37 |
4.0Â 6.0 | 2-8 10 12 14 | ||
KVVR | Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16Â 19 24 27 30 37 |
4.0Â 6.0 | 2-8 10 12 14 | ||
KVVRP | Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16Â 19 24 27 30 37 |
4.0Â 6.0 | 2-8 10 12 14 |
 flame-retardant control cable, XLPE insulated control cable, XLPE insulated flame-retardant control cable, low smoke halogen free flame-retardant control cable etc. power control cable
 Application
Â
The products are suitable for the wiring of electric controlling equipments and instrument, monitoring and controlling return circuit ,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750 AC.
Â
Construction
 1. Conductor
   Bare soft copper Class B or Class C concentrically strandedÂ
2. Insulation
   XLPE or PVC, colored for identification
3. Assembly
  Individual conductors are cabled, with non-hygroscopic fillers where necessary, to form a
  round compact core and wrapped with a binder. Two conductor versions are assembled flat
  parallel.
4. Shield
  Aluminum or copper wire, tape or braid
5. Sheath
  Black PVC
Advantages
  Low-capacitance
 Single, pair and multiple conductor available
 Color-coded conductors for easy identification
 Durable, flexible, all-weather jacket
 Available at 600V for general purpose and 1000V for heavy duty
Â
Specification
Â
Type | Name | Section Area(mm2) | No. of Core |
KVV | Copper Conductor, PVC Insulated and Sheathed control cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16Â 19 24 27 30 37 |
4.0Â 6.0 | 2-8 10 12 14 | ||
KVVP | Copper Conductor, PVC Insulated and Sheathed, Copper-braid Screened Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16Â 19 24 27 30 37 |
4.0Â 6.0 | 2-8 10 12 14 | ||
KVVP2 | Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16Â 19 24 27 30 37 |
4.0Â 6.0 | 2-8 10 12 14 | ||
KVVP2-22 | Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Steel-tape armored Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16Â 19 24 27 30 37 |
4.0Â 6.0 | 2-8 10 12 14 | ||
KVV22 | Copper Conductor, PVC Insulated and Sheathed, Steel-tape armored Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16Â 19 24 27 30 37 |
4.0Â 6.0 | 2-8 10 12 14 | ||
KVVR | Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16Â 19 24 27 30 37 |
4.0Â 6.0 | 2-8 10 12 14 | ||
KVVRP | Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16Â 19 24 27 30 37 |
4.0Â 6.0 | 2-8 10 12 14 |
 flame-retardant control cable, XLPE insulated control cable, XLPE insulated flame-retardant control cable, low smoke halogen free flame-retardant control cable etc. power control cable
Â
24 hours mechanical Timer
Instant indicator
Min.setting time:15 minutes. Max.setting timer:24 hours
With hand switch,can be switched to operating and
setting at any time
Instructions:
1. Set program: 1 pin is equivalent to 15 minutes. Determine desired start time and push down pins until desired
off time.
For instance, if you want electrical devices to work from 8:00am to 11:00am and from 13:00pm to 17:00pm, you
just need to put down allthe pins between the three period time.
2. Set the current time: Turning the dial clockwise until the arrow pointing to
current time.
For example,if now it is 8:00 am, please turn the dial and make sure the
arrow point to 8. (See the picture.)
3. Plug the electrical device directly into the timer. Make sure the electrical
device is power-on.
4. Plug the timer into electrical outlet and the electrical device will be work
according to the setting program.
Note: = Normal Ope n = Timing
Make sure the switch on the Timing position. If it
is on the [Normal Open" mode, the electrical device is
always power-on and the timer function no work.
Specifications:
Rated Voltage, Current and Power |
As shown on the label |
Time Setting Range |
15minutes24hours |
Working Temperature |
-10℃?+55℃ |
Operation |
Clockwise |
Insulation Resistance |
>100M |
Inherent Loss |
≤1W |
Application:
1. To enable high-power electric appliances to run automatically at off-peak time if there is different electricity
price according to different periods of time in some areas.
2. To use for electric appliances which need time control, such as water heaters, air conditioners, drinking
fountains, rice cookers, advertising lights and so on.
3. To control the charging time. For example, battery of electric bikes or mobile phones, storage batteries, etc.
4. Occasions which need switch on/off frequently, like interval spray irrigation for flowersand lawn, cyclical
adding oxygen to fish jar, fountains and so on.
5. Home safety precautions and lighting.
Caution:
1.D o not exceed the maximum ratings of the timer.
2.M ust reset the current time after power failure.
3.D o not plug the timer directly into the working electrical appliances.
4.U nless changing the setting, keep the program same every day.
5.D o not disassemble timer by yourself. Professionals service are needed for maintenance.
6.T his item is only for indoor use.
Mechanical Timer, mechanical timer socket, 24hr mechanical timer, mechanical timer plug, mechanical timer adaptor
NINGBO COWELL ELECTRONICS & TECHNOLOGY CO., LTD , https://www.cowellsocket.com