Product Description
Standards of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
Â
The cable is manufactured according to IEC 60502.2, IEC 60502.1, AS/NZS 1429.1, AS/NZS 5000.1, BS 6622/7835, BS 5467, BS 6746, BS 6346, VDE 0276, ASTM, ABNT etc. It is suitable to be installed in the power line with rated voltage from (U0/U)0.6/1kV to 19/33kV for power transmission.
Â
Application of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
Â
The electric cable is applied to transmit and distribute power in power transmission and distribution system of 1kV~35kV or lower. It is widely adopted in the fields including power, construction, industry, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power  cable and in partial re-place of PVC insulation or XLPE power cable.
Type &Â Designation of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
Â
Type | Description | Applications |
N2XY/N2XSEY NA2XY/NA2XSEY |
Cu or AL conductor XLPE insulated PVC sheathed power cables. | For laying indoors, in tunnels, in ducts. Able to bear extermal mechanical force but not large pulling forces. Single core cables are impermissible to be laid in magnetic ducts. |
N2X2Y/N2XSE2Y NA2X2Y/NA2XSE2Y |
Cu or AL conductor XLPE insulated PE sheathed power cables. | |
N2XBY/N2XSEBY NA2XBY/NA2XSEBY |
Cu or AL conductor XLPE insulated PVC sheathed internal steel tape armoured power cables. | For laying indoors, in tunnels, in ducts and underground. Able to bear extermal mechanical force but not large pulling forces, Impermissible to use single core cable in A.C circuit. |
N2XB2Y/N2XSEB2Y NA2XB2Y/NA2XSEB2Y |
Cu or AL conductor XLPE insulated PE sheathed internal steel tape armoured power cables. | |
N2XRY/N2XSERY NA2XRY/NA2XSERY |
Cu or AL conductor XLPE insulated PVC sheathed internal steel wire armoured power cables. | For laying in underground areas along route with large difference of elevation, in shafts and in water, able to bear a corresponding pulling forces and external mechanical forces. |
N2XR2Y/N2XSER2Y NA2XR2Y/NA2XSER2Y |
Cu or AL conductor XLPE insulated PE sheathed internal steel wire armoured power cables. |
Cable Properties of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
Â
Special features which we can offer for LV and MV cables:
* Watertight construction (both radial and longitudinal).
* Resistant to heavy vibration.
* Available in long delivery lengths to reduce number of joints.
* Corrosion-free screen area.
* Copper or aluminum conductor up to 2500mm².
* Different options for outer PE jackets (LDPE, MDPE &Â HDPE).
* Different options for PVC, LSF, LSZH &Â FRPVC, being anti-termite or UV resistant as perÂ
   BS 7835, IEC 60332 etc.
* Strippable insulation screen.
* Increased armour conductivity by insertion of hard drawn copper wires in armour.
Â
The maximum rated temperature of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
Â
XLPE insulated,the maximum operating temperature of conductor shall exceed 90ºCwhen the cable is used for long not period. The temperature of conductor shall not exceed 250ºC at short circuit for 5 seconds.
PVC insulated,the maximum operating temperature of conductor shall exceed 90ºC or 70 ºC  when the cable is used for long not period. PVC insulated the temperature of conductor shall not exceed 160ºC at short circuit for 5 seconds.
Â
Installation requirement of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
Â
The installation of cable is not limited by the difference of elevation along the route. The ambient temperature should not be below 0ºC during installation. The permissible bending radius for cable shall be complied with the following regulations:
For single-core: R>20(D+d) +/-5%
For multi-core: R>15(D+d) +/-5%
Where:R-bending radius (mm) , D-overall diameter of the cable (mm) , d-diameter of conductor (mm).
Single core cable of using in AC circuit shall be without armour or with steel wire armour and shall not be laid in magnetic ducs.
Â
Rated voltage, No. of core and range of sectional area
Â
Rate Voltage(kv): 0.6/1kVÂ Â 1.8/3kVÂ Â Â Â 3.6/6kVÂ Â Â Â 6/10kVÂ Â Â Â Â Â 8.7/15kVÂ Â Â 12/20kVÂ Â
                         18/30kV  21/35kV Â
    Equivalent to : 0.6/1kV  1.9/3.3kV  3.8/6.6kV  6.35/11kV  8.7/15kV   12.7/22kVÂ
                         19/33kV   21/35kV
Â
No. of core and sectional area(mm2):
Â
1 Core 1.5-800Â Â Â Â 25-800Â Â Â Â 25-1200Â Â Â Â 25-1200Â Â Â Â 35-1200Â Â Â Â 50-1200Â Â Â Â 50-1200Â
          50-1200Â
2 Core 1.5-185Â Â Â Â Â 25-185Â
3 Core 1.5-400Â Â Â Â Â 25-400Â Â Â Â Â 25-400Â Â Â Â Â 25-400Â Â Â Â Â 35-400Â Â Â Â Â 50-400Â Â Â Â Â 50-400Â Â
          50-400Â
4 Core 2.5-400Â Â Â Â Â 25-400Â
5 Core 2.5-400Â Â Â Â Â 25-400
Â
Contact: Justin Zhang
Marketing Manager
Henan Jiapu Cable Co., Ltd
Direct Tel: +86-371-6866 5329 Ext.611
Direct Fax: +86-371-6938 6788
Mobile No.: +86-135 9807 3108
Â
website: www.jiapucable.com UG cable 3x150mm2 copper 18/30 (36) kV XLPE insualted/ PVC sheath with armour to Iraq
Product Description
Standards of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
Â
The cable is manufactured according to IEC 60502.2, IEC 60502.1, AS/NZS 1429.1, AS/NZS 5000.1, BS 6622/7835, BS 5467, BS 6746, BS 6346, VDE 0276, ASTM, ABNT etc. It is suitable to be installed in the power line with rated voltage from (U0/U)0.6/1kV to 19/33kV for power transmission.
Â
Application of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
Â
The electric cable is applied to transmit and distribute power in power transmission and distribution system of 1kV~35kV or lower. It is widely adopted in the fields including power, construction, industry, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power  cable and in partial re-place of PVC insulation or XLPE power cable.
Type &Â Designation of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
Â
Type | Description | Applications |
N2XY/N2XSEY NA2XY/NA2XSEY |
Cu or AL conductor XLPE insulated PVC sheathed power cables. | For laying indoors, in tunnels, in ducts. Able to bear extermal mechanical force but not large pulling forces. Single core cables are impermissible to be laid in magnetic ducts. |
N2X2Y/N2XSE2Y NA2X2Y/NA2XSE2Y |
Cu or AL conductor XLPE insulated PE sheathed power cables. | |
N2XBY/N2XSEBY NA2XBY/NA2XSEBY |
Cu or AL conductor XLPE insulated PVC sheathed internal steel tape armoured power cables. | For laying indoors, in tunnels, in ducts and underground. Able to bear extermal mechanical force but not large pulling forces, Impermissible to use single core cable in A.C circuit. |
N2XB2Y/N2XSEB2Y NA2XB2Y/NA2XSEB2Y |
Cu or AL conductor XLPE insulated PE sheathed internal steel tape armoured power cables. | |
N2XRY/N2XSERY NA2XRY/NA2XSERY |
Cu or AL conductor XLPE insulated PVC sheathed internal steel wire armoured power cables. | For laying in underground areas along route with large difference of elevation, in shafts and in water, able to bear a corresponding pulling forces and external mechanical forces. |
N2XR2Y/N2XSER2Y NA2XR2Y/NA2XSER2Y |
Cu or AL conductor XLPE insulated PE sheathed internal steel wire armoured power cables. |
Cable Properties of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
Â
Special features which we can offer for LV and MV cables:
* Watertight construction (both radial and longitudinal).
* Resistant to heavy vibration.
* Available in long delivery lengths to reduce number of joints.
* Corrosion-free screen area.
* Copper or aluminum conductor up to 2500mm².
* Different options for outer PE jackets (LDPE, MDPE &Â HDPE).
* Different options for PVC, LSF, LSZH &Â FRPVC, being anti-termite or UV resistant as perÂ
   BS 7835, IEC 60332 etc.
* Strippable insulation screen.
* Increased armour conductivity by insertion of hard drawn copper wires in armour.
Â
The maximum rated temperature of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
Â
XLPE insulated,the maximum operating temperature of conductor shall exceed 90ºCwhen the cable is used for long not period. The temperature of conductor shall not exceed 250ºC at short circuit for 5 seconds.
PVC insulated,the maximum operating temperature of conductor shall exceed 90ºC or 70 ºC  when the cable is used for long not period. PVC insulated the temperature of conductor shall not exceed 160ºC at short circuit for 5 seconds.
Â
Installation requirement of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
Â
The installation of cable is not limited by the difference of elevation along the route. The ambient temperature should not be below 0ºC during installation. The permissible bending radius for cable shall be complied with the following regulations:
For single-core: R>20(D+d) +/-5%
For multi-core: R>15(D+d) +/-5%
Where:R-bending radius (mm) , D-overall diameter of the cable (mm) , d-diameter of conductor (mm).
Single core cable of using in AC circuit shall be without armour or with steel wire armour and shall not be laid in magnetic ducs.
Â
Rated voltage, No. of core and range of sectional area
Â
Rate Voltage(kv): 0.6/1kVÂ Â 1.8/3kVÂ Â Â Â 3.6/6kVÂ Â Â Â 6/10kVÂ Â Â Â Â Â 8.7/15kVÂ Â Â 12/20kVÂ Â
                         18/30kV  21/35kV Â
    Equivalent to : 0.6/1kV  1.9/3.3kV  3.8/6.6kV  6.35/11kV  8.7/15kV   12.7/22kVÂ
                         19/33kV   21/35kV
Â
No. of core and sectional area(mm2):
Â
1 Core 1.5-800Â Â Â Â 25-800Â Â Â Â 25-1200Â Â Â Â 25-1200Â Â Â Â 35-1200Â Â Â Â 50-1200Â Â Â Â 50-1200Â
          50-1200Â
2 Core 1.5-185Â Â Â Â Â 25-185Â
3 Core 1.5-400Â Â Â Â Â 25-400Â Â Â Â Â 25-400Â Â Â Â Â 25-400Â Â Â Â Â 35-400Â Â Â Â Â 50-400Â Â Â Â Â 50-400Â Â
          50-400Â
4 Core 2.5-400Â Â Â Â Â 25-400Â
5 Core 2.5-400Â Â Â Â Â 25-400
Â
Contact: Justin Zhang
Marketing Manager
Henan Jiapu Cable Co., Ltd
Direct Tel: +86-371-6866 5329 Ext.611
Direct Fax: +86-371-6938 6788
Mobile No.: +86-135 9807 3108
Â
website: www.jiapucable.com
Function description
The socket is ordinary converter,with two output 5V2A power USB power supply at the same time,can be very convenient in use electrical appliances and recharge the equipment at the same time,such as digital products like Iphone Ipad,MP3,MP4 etc.The charge apply to full range of international AC output,no-load power consumption less than 0.3W,with short circuit,overload,over-voltage protection,can be convenient for your life and save more energy
Timer Control Time Adgustment
1.Press the power switch 1 time,the 1HOUR LED will light on.The Timer into ON mode,USB and control socket output ON .
2.Continuously press the power switch the LED light on,the Countdown mode and LED light on will cycle change from 1HR,2HR,4HR,6HR,8HR,10HR.
3.Choose you need countdown time mode,the mode LED will lighto on,start countdown until countdown time finish,the control output and USB change to OFF
4.Then the countdown is start,The Time indicate LED will from high to low auto change until Countdown finish off.
Failure analysis:
1.check whether the power supply connection is good
2.check whether the USB cable is loosen
Warning Note:
1.Use indoor and dry location ONLY
2.The load max does not exceed 15A 3600W
3.This product does not convert voltage please do not miss use DO NOT exceed the maximum loading of 3600 Watts 15A
4.Always have earth connection for safety reason
5.If in doubt please consult with a qualified electrician
USB Countdown Timer, USB Countdown Timer Socket, USB Timer, USB Charger Timer, USB Timer Socket
NINGBO COWELL ELECTRONICS & TECHNOLOGY CO., LTD , https://www.cowellsockets.com