Model NO.: NYRY
Wire Core Material: Copper
Certification: CCC, CE
Model: Nyby, Nyry
Brand: Jl
Rated Voltage: 0.6/1 Kv
Number of Core: 1-5
Refer Standard: IEC 60502-1
Type of Armor: Swa or Sta
Trademark: JL
Transport Package: Wooden Drum/Steel Drum
Specification: 1.5-400 Mm2
Origin: Jiangsu, China
HS Code: 8544492100
Model NO.: NYRY
Wire Core Material: Copper
Certification: CCC, CE
Model: Nyby, Nyry
Brand: Jl
Rated Voltage: 0.6/1 Kv
Number of Core: 1-5
Refer Standard: IEC 60502-1
Type of Armor: Swa or Sta
Trademark: JL
Transport Package: Wooden Drum/Steel Drum
Specification: 1.5-400 Mm2
Origin: Jiangsu, China
HS Code: 8544492100

Low Voltage PVC Insulated Power Armoured Cables Construction:
Copper or Aluminum Conductor , PVC Insulation, Aluminum/galvanized steel wires or Double Steel /Aluminum Tape Armour, PVC Sheathed
Low Voltage PVC Insulated Power Armoured Cables Application:
IEC 60502-1 cables are used for electricity supply in low voltage installation system, IEC 60502-1 cables are
suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations,
local energy distributions, industrial plants, where there is no risk of mechanical damage.
Low Voltage PVC Insulated Power Armoured Cables Colour Code:
1 Core :Â | Red or Black |
2 Cores :Â | Red, Black |
3 Cores :Â | Red, Yellow, Blue |
4 Cores :Â | Red, Yellow, Blue, Black |
5 Cores :Â | Red, Yellow, Blue, Black, Green |
Above 5 Cores:Â | Black Cores with White numerals |
Colour Code (2) : | |
1 Core : | Brown or Blue |
2 Cores :Â | Brown or Blue |
3 Cores : | Brown, Black, Grey |
4 Cores :Â | Blue, Brown, Black, Grey |
5 Cores :Â | Green/Yellow, Blue, Brown, Black, Grey |
Above 5 Cores: | Black Cores with White numerals |
Low Voltage PVC Insulated Power Armoured Cables Technical Data:
Conductor: Â Copper or Aluminium conductor, round standed or Shaped,solid round conductor(Class1)or stranded Conductor(Class2) ,
Test Voltage:Â 4000V
Working Temperature:-5-70 º C
Short-circuit max. Conductor temperature:160°C
Insulation resistance: 20 MΩ x km
Parameter:
Two cores(Galvanized steel wire armoured)
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
2x2.5 | 1.8 | 0.8 | 1 | 0.8 | 1.8 | 14 |
2x4 | 2.3 | 1 | 1 | 1.25 | 1.8 | 16.7 |
2x6 | 2.8 | 1 | 1 | 1.25 | 1.8 | 17.7 |
2x10 | 3.6 | 1 | 1 | 1.25 | 1.8 | 19.3 |
2x16 | 4.5 | 1 | 1 | 1.25 | 1.8 | 21.1 |
2x25 | 5.6 | 1.2 | 1 | 1.6 | 1.8 | 24.8 |
2x35 | 6.7 | 1.2 | 1 | 1.6 | 1.8 | 27 |
2x50 | 8 | 1.4 | 1 | 1.6 | 1.9 | 30.7 |
2x70 | 9.4 | 1.4 | 1 | 2 | 2.1 | 34.5 |
2x95 | 11 | 1.6 | 1.2 | 2 | 2.2 | 39.2 |
2x120 | 12.4 | 1.6 | 1.2 | 2 | 2.3 | 42.2 |
2x150 | 13.8 | 1.8 | 1.2 | 2.5 | 2.5 | 47.2 |
2x185 | 15.3 | 2 | 1.4 | 2.5 | 2.6 | 51.6 |
2x240 | 17.5 | 2.2 | 1.4 | 2.5 | 2.8 | 57.2 |
2x300 | 19.5 | 2.4 | 1.6 | 2.5 | 3 | 62.8 |
2x400 | 22.6 | 2.6 | 1.6 | 2.5 | 3.2 | 70.3 |
Three cores(Galvanized steel wire armoured)
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
 |  |
mm² | mm | mm | mm | mm | mm | mm |  |  |
3x2.5 | 1.8 | 0.8 | 1 | 0.8 | 1.8 | 14.5 | Â | Â |
3x4 | 2.3 | 1 | 1 | 1.25 | 1.8 | 17.4 | Â | Â |
3x6 | 2.8 | 1 | 1 | 1.25 | 1.8 | 18.4 | Â | Â |
3x10 | 3.6 | 1 | 1 | 1.25 | 1.8 | 20.2 | Â | Â |
3x16 | 4.5 | 1 | 1 | 1.6 | 1.8 | 22.8 | Â | Â |
3x25 | 5.6 | 1.2 | 1 | 1.6 | 1.9 | 26 | Â | Â |
3x35 | 6.7 | 1.2 | 1 | 1.6 | 1.9 | 28.5 | Â | Â |
3x50 | 8 | 1.4 | 1 | 2 | 2 | 33.3 | Â | Â |
3x70 | 9.4 | 1.4 | 1.2 | 2 | 2.1 | 37 | Â | Â |
3x95 | 11 | 1.6 | 1.2 | 2 | 2.3 | 41.6 | Â | Â |
3x120 | 12.4 | 1.6 | 1.2 | 2.5 | 2.4 | 45.9 | Â | Â |
3x150 | 13.8 | 1.8 | 1.4 | 2.5 | 2.6 | 50.4 | Â | Â |
3x185 | 15.3 | 2 | 1.4 | 2.5 | 2.7 | 54.8 | Â | Â |
3x240 | 17.5 | 2.2 | 1.5 | 2.5 | 2.9 | 61.2 | Â | Â |
3x300 | 19.5 | 2.4 | 1.6 | 2.5 | 3.1 | 66.8 | Â | Â |
3x400 | 22.6 | 2.8 | 1.6 | 3.15 | 3.4 | 76.7 | Â | Â |
3x500 | 25.2 | 2.8 | 1.8 | 3.15 | 3.7 | 83.6 | Â | Â |
 |  |  |  |  |  |  |  |  |
Three cores+1(Galvanized steel wire armoured) | Â | Â | ||||||
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
||
mm² | mm | mm | mm | mm | mm | mm | mm | mm |
3x10 +6 | 3.6 | 2.8 | 1 | 1 | 1 | 1.25 | 1.8 | 21.9 |
3x16 +10 | 4.5 | 3.6 | 1 | 1 | 1 | 1.6 | 1.8 | 24.2 |
3x25 +16 | 5.6 | 4.5 | 1.2 | 1 | 1 | 1.6 | 1.8 | 27.9 |
3x35 +16 | 6.7 | 4.5 | 1.2 | 1 | 1 | 1.6 | 1.9 | 30.8 |
3x50 +25 | 8 | 5.6 | 1.4 | 1.2 | 1 | 2 | 2 | 36.4 |
3x70 +35 | 9.4 | 6.7 | 1.4 | 1.2 | 1.2 | 2 | 2.1 | 40.1 |
3x95 +50 | 11 | 8 | 1.6 | 1.4 | 1.2 | 2.5 | 2.3 | 46.3 |
3x120 +70 | 12.4 | 9.4 | 1.6 | 1.4 | 1.4 | 2.5 | 2.4 | 50.3 |
3x150 +70 | 13.8 | 9.4 | 1.8 | 1.4 | 1.4 | 2.5 | 2.6 | 55 |
3x185 +95 | 15.3 | 11 | 2 | 1.6 | 1.4 | 2.5 | 2.7 | 60.3 |
3x240 +120 | 17.5 | 12.4 | 2.2 | 1.6 | 1.6 | 2.5 | 2.9 | 67 |
Four cores(Galvanized steel wire armoured)
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
4x4 | 2.3 | 1 | 1 | 1.25 | 1.8 | 18.5 |
4x6 | 2.8 | 1 | 1 | 1.25 | 1.8 | 19.7 |
4x10 | 3.6 | 1 | 1 | 1.25 | 1.8 | 22.3 |
4x16 | 4.5 | 1 | 1 | 1.6 | 1.8 | 24.5 |
4x25 | 5.6 | 1.2 | 1 | 1.6 | 1.9 | 28.2 |
4x35 | 6.7 | 1.2 | 1 | 1.6 | 2 | 31.1 |
4x50 | 8 | 1.4 | 1 | 2 | 2.1 | 36.7 |
4x70 | 9.4 | 1.4 | 1.2 | 2 | 2.3 | 40.4 |
4x95 | 11 | 1.6 | 1.2 | 2.5 | 2.5 | 46.6 |
4x120 | 12.4 | 1.6 | 1.4 | 2.5 | 2.6 | 50.6 |
4x150 | 13.8 | 1.8 | 1.4 | 2.5 | 2.7 | 55.3 |
4x185 | 15.3 | 2 | 1.4 | 2.5 | 2.9 | 60.6 |
4x240 | 17.5 | 2.2 | 1.6 | 2.5 | 3.1 | 67.3 |
4x300 | 19.5 | 2.4 | 1.6 | 3.15 | 3.4 | 74.9 |
4x400 | 22.6 | 2.6 | 1.8 | 3.15 | 3.7 | 84.4 |
4x500 | 25.2 | 2.8 | 2 | 3.15 | 3.9 | 92.1 |





Â

Low Voltage PVC Insulated Power Armoured Cables Construction:
Copper or Aluminum Conductor , PVC Insulation, Aluminum/galvanized steel wires or Double Steel /Aluminum Tape Armour, PVC Sheathed
Low Voltage PVC Insulated Power Armoured Cables Application:
IEC 60502-1 cables are used for electricity supply in low voltage installation system, IEC 60502-1 cables are
suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations,
local energy distributions, industrial plants, where there is no risk of mechanical damage.
Low Voltage PVC Insulated Power Armoured Cables Colour Code:
1 Core :Â | Red or Black |
2 Cores :Â | Red, Black |
3 Cores :Â | Red, Yellow, Blue |
4 Cores :Â | Red, Yellow, Blue, Black |
5 Cores :Â | Red, Yellow, Blue, Black, Green |
Above 5 Cores:Â | Black Cores with White numerals |
Colour Code (2) : | |
1 Core : | Brown or Blue |
2 Cores :Â | Brown or Blue |
3 Cores : | Brown, Black, Grey |
4 Cores :Â | Blue, Brown, Black, Grey |
5 Cores :Â | Green/Yellow, Blue, Brown, Black, Grey |
Above 5 Cores: | Black Cores with White numerals |
Low Voltage PVC Insulated Power Armoured Cables Technical Data:
Conductor: Â Copper or Aluminium conductor, round standed or Shaped,solid round conductor(Class1)or stranded Conductor(Class2) ,
Test Voltage:Â 4000V
Working Temperature:-5-70 º C
Short-circuit max. Conductor temperature:160°C
Insulation resistance: 20 MΩ x km
Parameter:
Two cores(Galvanized steel wire armoured)
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
2x2.5 | 1.8 | 0.8 | 1 | 0.8 | 1.8 | 14 |
2x4 | 2.3 | 1 | 1 | 1.25 | 1.8 | 16.7 |
2x6 | 2.8 | 1 | 1 | 1.25 | 1.8 | 17.7 |
2x10 | 3.6 | 1 | 1 | 1.25 | 1.8 | 19.3 |
2x16 | 4.5 | 1 | 1 | 1.25 | 1.8 | 21.1 |
2x25 | 5.6 | 1.2 | 1 | 1.6 | 1.8 | 24.8 |
2x35 | 6.7 | 1.2 | 1 | 1.6 | 1.8 | 27 |
2x50 | 8 | 1.4 | 1 | 1.6 | 1.9 | 30.7 |
2x70 | 9.4 | 1.4 | 1 | 2 | 2.1 | 34.5 |
2x95 | 11 | 1.6 | 1.2 | 2 | 2.2 | 39.2 |
2x120 | 12.4 | 1.6 | 1.2 | 2 | 2.3 | 42.2 |
2x150 | 13.8 | 1.8 | 1.2 | 2.5 | 2.5 | 47.2 |
2x185 | 15.3 | 2 | 1.4 | 2.5 | 2.6 | 51.6 |
2x240 | 17.5 | 2.2 | 1.4 | 2.5 | 2.8 | 57.2 |
2x300 | 19.5 | 2.4 | 1.6 | 2.5 | 3 | 62.8 |
2x400 | 22.6 | 2.6 | 1.6 | 2.5 | 3.2 | 70.3 |
Three cores(Galvanized steel wire armoured)
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
 |  |
mm² | mm | mm | mm | mm | mm | mm |  |  |
3x2.5 | 1.8 | 0.8 | 1 | 0.8 | 1.8 | 14.5 | Â | Â |
3x4 | 2.3 | 1 | 1 | 1.25 | 1.8 | 17.4 | Â | Â |
3x6 | 2.8 | 1 | 1 | 1.25 | 1.8 | 18.4 | Â | Â |
3x10 | 3.6 | 1 | 1 | 1.25 | 1.8 | 20.2 | Â | Â |
3x16 | 4.5 | 1 | 1 | 1.6 | 1.8 | 22.8 | Â | Â |
3x25 | 5.6 | 1.2 | 1 | 1.6 | 1.9 | 26 | Â | Â |
3x35 | 6.7 | 1.2 | 1 | 1.6 | 1.9 | 28.5 | Â | Â |
3x50 | 8 | 1.4 | 1 | 2 | 2 | 33.3 | Â | Â |
3x70 | 9.4 | 1.4 | 1.2 | 2 | 2.1 | 37 | Â | Â |
3x95 | 11 | 1.6 | 1.2 | 2 | 2.3 | 41.6 | Â | Â |
3x120 | 12.4 | 1.6 | 1.2 | 2.5 | 2.4 | 45.9 | Â | Â |
3x150 | 13.8 | 1.8 | 1.4 | 2.5 | 2.6 | 50.4 | Â | Â |
3x185 | 15.3 | 2 | 1.4 | 2.5 | 2.7 | 54.8 | Â | Â |
3x240 | 17.5 | 2.2 | 1.5 | 2.5 | 2.9 | 61.2 | Â | Â |
3x300 | 19.5 | 2.4 | 1.6 | 2.5 | 3.1 | 66.8 | Â | Â |
3x400 | 22.6 | 2.8 | 1.6 | 3.15 | 3.4 | 76.7 | Â | Â |
3x500 | 25.2 | 2.8 | 1.8 | 3.15 | 3.7 | 83.6 | Â | Â |
 |  |  |  |  |  |  |  |  |
Three cores+1(Galvanized steel wire armoured) | Â | Â | ||||||
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
||
mm² | mm | mm | mm | mm | mm | mm | mm | mm |
3x10 +6 | 3.6 | 2.8 | 1 | 1 | 1 | 1.25 | 1.8 | 21.9 |
3x16 +10 | 4.5 | 3.6 | 1 | 1 | 1 | 1.6 | 1.8 | 24.2 |
3x25 +16 | 5.6 | 4.5 | 1.2 | 1 | 1 | 1.6 | 1.8 | 27.9 |
3x35 +16 | 6.7 | 4.5 | 1.2 | 1 | 1 | 1.6 | 1.9 | 30.8 |
3x50 +25 | 8 | 5.6 | 1.4 | 1.2 | 1 | 2 | 2 | 36.4 |
3x70 +35 | 9.4 | 6.7 | 1.4 | 1.2 | 1.2 | 2 | 2.1 | 40.1 |
3x95 +50 | 11 | 8 | 1.6 | 1.4 | 1.2 | 2.5 | 2.3 | 46.3 |
3x120 +70 | 12.4 | 9.4 | 1.6 | 1.4 | 1.4 | 2.5 | 2.4 | 50.3 |
3x150 +70 | 13.8 | 9.4 | 1.8 | 1.4 | 1.4 | 2.5 | 2.6 | 55 |
3x185 +95 | 15.3 | 11 | 2 | 1.6 | 1.4 | 2.5 | 2.7 | 60.3 |
3x240 +120 | 17.5 | 12.4 | 2.2 | 1.6 | 1.6 | 2.5 | 2.9 | 67 |
Four cores(Galvanized steel wire armoured)
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
4x4 | 2.3 | 1 | 1 | 1.25 | 1.8 | 18.5 |
4x6 | 2.8 | 1 | 1 | 1.25 | 1.8 | 19.7 |
4x10 | 3.6 | 1 | 1 | 1.25 | 1.8 | 22.3 |
4x16 | 4.5 | 1 | 1 | 1.6 | 1.8 | 24.5 |
4x25 | 5.6 | 1.2 | 1 | 1.6 | 1.9 | 28.2 |
4x35 | 6.7 | 1.2 | 1 | 1.6 | 2 | 31.1 |
4x50 | 8 | 1.4 | 1 | 2 | 2.1 | 36.7 |
4x70 | 9.4 | 1.4 | 1.2 | 2 | 2.3 | 40.4 |
4x95 | 11 | 1.6 | 1.2 | 2.5 | 2.5 | 46.6 |
4x120 | 12.4 | 1.6 | 1.4 | 2.5 | 2.6 | 50.6 |
4x150 | 13.8 | 1.8 | 1.4 | 2.5 | 2.7 | 55.3 |
4x185 | 15.3 | 2 | 1.4 | 2.5 | 2.9 | 60.6 |
4x240 | 17.5 | 2.2 | 1.6 | 2.5 | 3.1 | 67.3 |
4x300 | 19.5 | 2.4 | 1.6 | 3.15 | 3.4 | 74.9 |
4x400 | 22.6 | 2.6 | 1.8 | 3.15 | 3.7 | 84.4 |
4x500 | 25.2 | 2.8 | 2 | 3.15 | 3.9 | 92.1 |





Â
Fiber Optic Adapter,Lc Fiber Optic Adapter,Lc Om3 Fiber Optic Adapter
ZHW Technology Co., Ltd. , http://www.gdfiberadapter.com